re-uploading work

This commit is contained in:
2026-02-04 17:46:30 -06:00
commit 3b14c65998
1388 changed files with 381262 additions and 0 deletions

View File

@@ -0,0 +1,142 @@
# Timer Sensor Fix - Incorrect Entrypoint Binary
**Date:** 2025-01-30
**Status:** Complete
## Problem
The timer sensor was generating a handful of events immediately after a rule was enabled, but then would halt completely. Investigation revealed that events were being created for a few seconds, then the sensor process would stop.
### Symptoms
- Initial burst of 3-4 events when rule enabled
- Sensor process would die immediately after
- No ongoing event generation
- Zombie process (`defunct`) visible in process list
### Example Timeline
```
08:18:00 - Events 19, 20, 21, 22 created
08:18:06 - Events 23, 24 created
08:18:07 - Events 25, 26 created
08:18:07 - Sensor stopped (no more events)
```
## Root Cause
The sensor YAML configuration (`packs/core/sensors/interval_timer_sensor.yaml`) was referencing the wrong entrypoint:
```yaml
# INCORRECT - binary with different expectations
entry_point: attune-core-timer-sensor
```
The `attune-core-timer-sensor` binary was a compiled executable that expected different environment variables than what the sensor service provides. Specifically, it required `ATTUNE_API_URL` which was not being set:
```
Error: ATTUNE_API_URL environment variable is required
Caused by:
environment variable not found
```
This caused the sensor process to exit immediately after startup, but not before emitting a few events that were already buffered.
## Solution
Updated the sensor entrypoint to use the Python implementation which is designed to work with the sensor service's protocol:
```yaml
# CORRECT - Python script compatible with sensor service
entry_point: interval_timer_sensor.py
```
### Files Changed
1. **Configuration**: `attune/packs/core/sensors/interval_timer_sensor.yaml`
- Changed `entry_point` from `attune-core-timer-sensor` to `interval_timer_sensor.py`
2. **Database**: Updated sensor record directly
```sql
UPDATE sensor
SET entrypoint = 'interval_timer_sensor.py'
WHERE ref = 'core.interval_timer_sensor';
```
## Verification
After the fix, the sensor operates correctly:
1. **Process Running**: Python sensor process visible and active
```bash
$ ps aux | grep interval_timer_sensor.py
python3 ./packs/core/sensors/interval_timer_sensor.py
```
2. **Consistent Event Generation**: Events created every second as configured
```
08:20:57 - Event 32 created
08:20:58 - Event 33 created
08:20:59 - Event 34 created
08:21:00 - Event 35 created
08:21:01 - Event 36 created
(continuing indefinitely...)
```
3. **No Process Crashes**: No defunct/zombie processes, sensor continues running
4. **Database Verification**: Confirmed ongoing event creation
```sql
SELECT COUNT(*) FROM event WHERE created > NOW() - INTERVAL '1 minute';
-- Result: 60 events (one per second for 1 minute)
```
## Technical Details
### Python Sensor vs Binary Sensor
**Python Sensor (`interval_timer_sensor.py`)**:
- Reads trigger instances from `ATTUNE_SENSOR_TRIGGERS` environment variable
- Emits events as JSON to stdout
- Manages state internally (last fired times, intervals)
- Compatible with sensor service's process management
- No additional environment variables required
**Binary Sensor (`attune-core-timer-sensor`)**:
- Unknown implementation details (compiled binary)
- Required `ATTUNE_API_URL` environment variable
- Not compatible with sensor service's current protocol
- Purpose/origin unclear - possibly from earlier development phase
### Sensor Service Protocol
The sensor service manages long-running sensors by:
1. Starting sensor process with trigger instances in `ATTUNE_SENSOR_TRIGGERS`
2. Reading JSON events from sensor's stdout
3. Parsing events and generating system events
4. Matching events against rules and creating enforcements
5. Monitoring process health and logging stderr
## Lessons Learned
1. **Entrypoint Validation**: Sensor entrypoints should be validated to ensure they're compatible with the sensor service protocol
2. **Error Handling**: Sensor process failures should be more visible - the sensor appeared to "work" initially because buffered events were emitted before the process died
3. **Documentation**: Binary entrypoints should be documented if they have special requirements
4. **Testing**: Integration tests should verify sensors continue running beyond initial startup
## Future Improvements
1. **Health Checks**: Add periodic health checks for long-running sensors
2. **Auto-Restart**: Automatically restart failed sensor processes
3. **Better Logging**: Surface sensor process failures more prominently
4. **Validation**: Validate sensor entrypoints during pack loading
5. **Remove Binary**: Consider removing or documenting the `attune-core-timer-sensor` binary if it's not needed
## Related Files
- `attune/packs/core/sensors/interval_timer_sensor.yaml` - Sensor configuration
- `attune/packs/core/sensors/interval_timer_sensor.py` - Python sensor implementation
- `attune/packs/core/sensors/attune-core-timer-sensor` - Binary (unused/incorrect)
- `attune/crates/sensor/src/sensor_manager.rs` - Sensor process management
## Status: ✅ RESOLVED