# Timer Sensor Fix - Incorrect Entrypoint Binary
|
||||
|
||||
**Date:** 2025-01-30
|
||||
**Status:** Complete
|
||||
|
||||
## Problem
|
||||
|
||||
The timer sensor was generating a handful of events immediately after a rule was enabled, but then would halt completely. Investigation revealed that events were being created for a few seconds, then the sensor process would stop.
|
||||
|
||||
### Symptoms
|
||||
- Initial burst of 3-4 events when rule enabled
|
||||
- Sensor process would die immediately after
|
||||
- No ongoing event generation
|
||||
- Zombie process (`defunct`) visible in process list
|
||||
|
||||
### Example Timeline
|
||||
```
|
||||
08:18:00 - Events 19, 20, 21, 22 created
|
||||
08:18:06 - Events 23, 24 created
|
||||
08:18:07 - Events 25, 26 created
|
||||
08:18:07 - Sensor stopped (no more events)
|
||||
```
|
||||
|
||||
## Root Cause
|
||||
|
||||
The sensor YAML configuration (`packs/core/sensors/interval_timer_sensor.yaml`) was referencing the wrong entrypoint:
|
||||
|
||||
```yaml
|
||||
# INCORRECT - binary with different expectations
|
||||
entry_point: attune-core-timer-sensor
|
||||
```
|
||||
|
||||
The `attune-core-timer-sensor` binary was a compiled executable that expected different environment variables than what the sensor service provides. Specifically, it required `ATTUNE_API_URL` which was not being set:
|
||||
|
||||
```
|
||||
Error: ATTUNE_API_URL environment variable is required
|
||||
|
||||
Caused by:
|
||||
environment variable not found
|
||||
```
|
||||
|
||||
This caused the sensor process to exit immediately after startup, but not before emitting a few events that were already buffered.
|
||||
|
||||
## Solution
|
||||
|
||||
Updated the sensor entrypoint to use the Python implementation which is designed to work with the sensor service's protocol:
|
||||
|
||||
```yaml
|
||||
# CORRECT - Python script compatible with sensor service
|
||||
entry_point: interval_timer_sensor.py
|
||||
```
|
||||
|
||||
### Files Changed
|
||||
1. **Configuration**: `attune/packs/core/sensors/interval_timer_sensor.yaml`
|
||||
- Changed `entry_point` from `attune-core-timer-sensor` to `interval_timer_sensor.py`
|
||||
|
||||
2. **Database**: Updated sensor record directly
|
||||
```sql
|
||||
UPDATE sensor
|
||||
SET entrypoint = 'interval_timer_sensor.py'
|
||||
WHERE ref = 'core.interval_timer_sensor';
|
||||
```
|
||||
|
||||
## Verification
|
||||
|
||||
After the fix, the sensor operates correctly:
|
||||
|
||||
1. **Process Running**: Python sensor process visible and active
|
||||
```bash
|
||||
$ ps aux | grep interval_timer_sensor.py
|
||||
python3 ./packs/core/sensors/interval_timer_sensor.py
|
||||
```
|
||||
|
||||
2. **Consistent Event Generation**: Events created every second as configured
|
||||
```
|
||||
08:20:57 - Event 32 created
|
||||
08:20:58 - Event 33 created
|
||||
08:20:59 - Event 34 created
|
||||
08:21:00 - Event 35 created
|
||||
08:21:01 - Event 36 created
|
||||
(continuing indefinitely...)
|
||||
```
|
||||
|
||||
3. **No Process Crashes**: No defunct/zombie processes, sensor continues running
|
||||
|
||||
4. **Database Verification**: Confirmed ongoing event creation
|
||||
```sql
|
||||
SELECT COUNT(*) FROM event WHERE created > NOW() - INTERVAL '1 minute';
|
||||
-- Result: 60 events (one per second for 1 minute)
|
||||
```
|
||||
|
||||
## Technical Details
|
||||
|
||||
### Python Sensor vs Binary Sensor
|
||||
|
||||
**Python Sensor (`interval_timer_sensor.py`)**:
|
||||
- Reads trigger instances from `ATTUNE_SENSOR_TRIGGERS` environment variable
|
||||
- Emits events as JSON to stdout
|
||||
- Manages state internally (last fired times, intervals)
|
||||
- Compatible with sensor service's process management
|
||||
- No additional environment variables required
|
||||
|
||||
**Binary Sensor (`attune-core-timer-sensor`)**:
|
||||
- Unknown implementation details (compiled binary)
|
||||
- Required `ATTUNE_API_URL` environment variable
|
||||
- Not compatible with sensor service's current protocol
|
||||
- Purpose/origin unclear - possibly from earlier development phase
|
||||
|
||||
### Sensor Service Protocol
|
||||
|
||||
The sensor service manages long-running sensors by:
|
||||
1. Starting sensor process with trigger instances in `ATTUNE_SENSOR_TRIGGERS`
|
||||
2. Reading JSON events from sensor's stdout
|
||||
3. Parsing events and generating system events
|
||||
4. Matching events against rules and creating enforcements
|
||||
5. Monitoring process health and logging stderr
|
||||
|
||||
## Lessons Learned
|
||||
|
||||
1. **Entrypoint Validation**: Sensor entrypoints should be validated to ensure they're compatible with the sensor service protocol
|
||||
2. **Error Handling**: Sensor process failures should be more visible - the sensor appeared to "work" initially because buffered events were emitted before the process died
|
||||
3. **Documentation**: Binary entrypoints should be documented if they have special requirements
|
||||
4. **Testing**: Integration tests should verify sensors continue running beyond initial startup
|
||||
|
||||
## Future Improvements
|
||||
|
||||
1. **Health Checks**: Add periodic health checks for long-running sensors
|
||||
2. **Auto-Restart**: Automatically restart failed sensor processes
|
||||
3. **Better Logging**: Surface sensor process failures more prominently
|
||||
4. **Validation**: Validate sensor entrypoints during pack loading
|
||||
5. **Remove Binary**: Consider removing or documenting the `attune-core-timer-sensor` binary if it's not needed
|
||||
|
||||
## Related Files
|
||||
|
||||
- `attune/packs/core/sensors/interval_timer_sensor.yaml` - Sensor configuration
|
||||
- `attune/packs/core/sensors/interval_timer_sensor.py` - Python sensor implementation
|
||||
- `attune/packs/core/sensors/attune-core-timer-sensor` - Binary (unused/incorrect)
|
||||
- `attune/crates/sensor/src/sensor_manager.rs` - Sensor process management
|
||||
|
||||
## Status: ✅ RESOLVED
|
||||
|
||||
The timer sensor now runs continuously and generates events at the configured interval without stopping.
|
||||