# Event Generation Fix and Timer Sensor Cleanup
|
||||
|
||||
**Date:** 2026-02-04
|
||||
**Status:** Complete ✅
|
||||
|
||||
## Problem
|
||||
|
||||
Events were not being generated and inserted into the database, despite rules being configured. The timer sensor was outputting JSON to stdout but events were never created in the database.
|
||||
|
||||
## Root Cause Analysis
|
||||
|
||||
The system had **two timer sensor implementations**:
|
||||
|
||||
1. **`attune-timer-sensor`** (669KB) - Old subprocess-based sensor
|
||||
- Located in `crates/timer-sensor-subprocess/`
|
||||
- Outputs JSON events to stdout
|
||||
- Expects sensor manager to parse stdout and create events
|
||||
- Does NOT follow the documented sensor protocol
|
||||
|
||||
2. **`attune-core-timer-sensor`** (5.8MB) - Correct API-based sensor
|
||||
- Located in `crates/sensor-timer/`
|
||||
- Makes HTTP POST requests to `/events` API endpoint
|
||||
- Follows the documented sensor interface specification
|
||||
- Handles rule lifecycle, token refresh, and proper event creation
|
||||
|
||||
**The database was configured to use the wrong sensor** (`attune-timer-sensor`), causing events to be logged to stdout but never persisted to the database.
|
||||
|
||||
## Investigation Steps
|
||||
|
||||
1. **Initial symptom**: Events visible in logs but not in database
|
||||
```
|
||||
"fired_at":"2026-02-04T01:21:28.028878792+00:00"
|
||||
```
|
||||
|
||||
2. **Discovered sensor manager wasn't processing stdout**:
|
||||
- Sensor manager was just logging stdout, not parsing JSON
|
||||
- No event creation or rule matching logic in sensor manager
|
||||
|
||||
3. **Found documentation mismatch**:
|
||||
- `docs/sensors/sensor-interface.md` specifies sensors should POST to `/events` API
|
||||
- Old subprocess sensor was outputting to stdout instead
|
||||
|
||||
4. **Identified dual implementations**:
|
||||
- Both sensors were being built in Docker
|
||||
- Database pointed to wrong one
|
||||
|
||||
## Solution
|
||||
|
||||
### Part 1: Switch to Correct Sensor Binary
|
||||
|
||||
**Database Update:**
|
||||
```sql
|
||||
UPDATE sensor
|
||||
SET entrypoint = 'attune-core-timer-sensor'
|
||||
WHERE ref = 'core.interval_timer_sensor';
|
||||
```
|
||||
|
||||
**Fixed Trigger Parameters:**
|
||||
The proper sensor expects a tagged enum format:
|
||||
```json
|
||||
{
|
||||
"type": "interval",
|
||||
"interval": 1,
|
||||
"unit": "seconds"
|
||||
}
|
||||
```
|
||||
|
||||
Updated rules to include the missing `"type"` field:
|
||||
```sql
|
||||
UPDATE rule
|
||||
SET trigger_params = '{"type": "interval", "interval": 1, "unit": "seconds"}'
|
||||
WHERE trigger = 3;
|
||||
```
|
||||
|
||||
### Part 2: Remove Old Sensor Implementation
|
||||
|
||||
To prevent future confusion, completely removed the old subprocess-based sensor:
|
||||
|
||||
**Files Deleted:**
|
||||
- `crates/timer-sensor-subprocess/` - entire crate directory
|
||||
|
||||
**Files Modified:**
|
||||
- `Cargo.toml` - removed `timer-sensor-subprocess` from workspace members
|
||||
- `docker/Dockerfile` - removed build steps for `attune-timer-sensor` binary
|
||||
- `packs/core/sensors/interval_timer_sensor.yaml` - updated `entry_point` to `attune-core-timer-sensor`
|
||||
|
||||
## Verification
|
||||
|
||||
After the fix, the complete event-driven automation pipeline is working:
|
||||
|
||||
```
|
||||
Timer fires → Event created → Rule evaluated → Enforcement created → Execution runs → Action completes
|
||||
```
|
||||
|
||||
**Database verification:**
|
||||
```sql
|
||||
-- Events being created every second
|
||||
SELECT id, trigger_ref, created FROM event ORDER BY id DESC LIMIT 5;
|
||||
-- Results: id=965-974, trigger_ref=core.intervaltimer
|
||||
|
||||
-- Enforcements created for matching rules
|
||||
SELECT id, rule_ref, event, status FROM enforcement ORDER BY id DESC LIMIT 5;
|
||||
-- Results: Both rules (default.echo_every_second, core.echo_every_second) creating enforcements
|
||||
|
||||
-- Executions running and completing
|
||||
SELECT id, action_ref, status, result->'stdout' FROM execution ORDER BY id DESC LIMIT 5;
|
||||
-- Results: status=completed, stdout="Hello, World!\n"
|
||||
```
|
||||
|
||||
## Technical Details
|
||||
|
||||
### Sensor Manager Enhancement
|
||||
|
||||
Added `fetch_trigger_instances()` method to query enabled rules and pass their configurations to sensor subprocesses:
|
||||
|
||||
**File:** `crates/sensor/src/sensor_manager.rs`
|
||||
|
||||
```rust
|
||||
async fn fetch_trigger_instances(&self, trigger_id: Id) -> Result<Vec<serde_json::Value>> {
|
||||
let rows = sqlx::query(
|
||||
r#"
|
||||
SELECT *
|
||||
FROM rule
|
||||
WHERE trigger = $1
|
||||
AND enabled = TRUE
|
||||
"#,
|
||||
)
|
||||
.bind(trigger_id)
|
||||
.fetch_all(&self.inner.db)
|
||||
.await?;
|
||||
|
||||
let trigger_instances: Vec<serde_json::Value> = rows
|
||||
.into_iter()
|
||||
.map(|row| {
|
||||
let id: i64 = row.try_get("id").unwrap_or(0);
|
||||
let ref_str: String = row.try_get("ref").unwrap_or_default();
|
||||
let trigger_params: serde_json::Value = row
|
||||
.try_get("trigger_params")
|
||||
.unwrap_or(serde_json::json!({}));
|
||||
|
||||
serde_json::json!({
|
||||
"id": id,
|
||||
"ref": ref_str,
|
||||
"config": trigger_params
|
||||
})
|
||||
})
|
||||
.collect();
|
||||
|
||||
Ok(trigger_instances)
|
||||
}
|
||||
```
|
||||
|
||||
The sensor subprocess receives this via `ATTUNE_SENSOR_TRIGGERS` environment variable.
|
||||
|
||||
### Sensor Protocol Compliance
|
||||
|
||||
The correct sensor (`attune-core-timer-sensor`) follows the documented protocol:
|
||||
|
||||
1. **Initialization:**
|
||||
- Reads configuration from environment variables
|
||||
- Validates API connectivity
|
||||
- Provisions authentication token
|
||||
|
||||
2. **Rule Discovery:**
|
||||
- Fetches active rules for its trigger type from API
|
||||
- Subscribes to RabbitMQ for rule lifecycle events (created, enabled, disabled, deleted)
|
||||
|
||||
3. **Event Generation:**
|
||||
- Monitors timers based on rule configurations
|
||||
- POSTs to `/events` API endpoint when timers fire
|
||||
- API handles event creation, rule matching, and enforcement creation
|
||||
|
||||
4. **Token Management:**
|
||||
- Automatically refreshes tokens at 80% of TTL
|
||||
- Handles token expiration gracefully
|
||||
|
||||
## Remaining Artifacts
|
||||
|
||||
The old binary `attune-timer-sensor` may still exist in:
|
||||
- Running Docker containers (until rebuilt)
|
||||
- Local `target/` build directories (until cleaned)
|
||||
- Existing Docker images (until rebuilt)
|
||||
|
||||
These will be naturally cleaned up through normal build/deploy cycles.
|
||||
|
||||
## Lessons Learned
|
||||
|
||||
1. **Documentation is critical**: The sensor interface spec was correct, but an outdated implementation was still in the codebase
|
||||
2. **Name similarity caused confusion**: `attune-timer-sensor` vs `attune-core-timer-sensor` are easy to confuse
|
||||
3. **Remove deprecated code promptly**: Having two implementations led to using the wrong one
|
||||
4. **Database-driven configuration**: The sensor `entrypoint` in the database must match the correct binary name
|
||||
|
||||
## Impact
|
||||
|
||||
- ✅ Events are now being created and persisted to database
|
||||
- ✅ Rules are being evaluated and enforcements created
|
||||
- ✅ Actions are executing successfully
|
||||
- ✅ Complete end-to-end automation pipeline functional
|
||||
- ✅ Codebase cleaned up (removed ~1,200 lines of obsolete code)
|
||||
- ✅ Documentation and implementation now aligned
|
||||
|
||||
## Related Files
|
||||
|
||||
**Modified:**
|
||||
- `attune/crates/sensor/src/sensor_manager.rs` - Added trigger instance fetching
|
||||
- `attune/Cargo.toml` - Removed old crate from workspace
|
||||
- `attune/docker/Dockerfile` - Removed old binary build
|
||||
- `attune/packs/core/sensors/interval_timer_sensor.yaml` - Updated entry_point
|
||||
|
||||
**Deleted:**
|
||||
- `attune/crates/timer-sensor-subprocess/` (entire directory)
|
||||
|
||||
**Database:**
|
||||
- Updated `sensor.entrypoint` for `core.interval_timer_sensor`
|
||||
- Updated `rule.trigger_params` format to include `"type"` field
|
||||
Reference in New Issue
Block a user